Truetime 56000 Manual Lawn

Truetime 56000 Manual Lawn Average ratng: 6,3/10 8123 votes
•Body Style: Anti-Siphon, 3/4' Female NPT (54000) or 3/4' Slip Joint (54001)
•Operating pressure: 10–150 PSI (70 PSI recommended maximum)
• Solenoid: 24 V a.c., 60 Hz (nominal)
Inrush: 0.4 amps, 9.60 VA@ 24 V a.c., 60 Hz

Manual Description Size; Eaton 11 Repair Information: Model 11 Eaton Hydrostatic Transmissions: 1.39 MB: Download: GR11000 Golf Green Roller: Operation, Maintenance & Parts Manual. Camfrog pro ipa download link.

  1. Find the user manual you need for your lawn and garden product and more at ManualsOnline. Locate lawn edger manual. Tru-Test Edger TT-16LD or 60102.
  2. Honda 160cc Lawn Mower Engine Manual. Honda 160cc Lawn Mower Engine Manual - I realize that you're trying to find articles on our blog within the headline Honda 160cc Lawn Mower Engine Manual of choices of articles that we got. If you are trying to find Honda 160cc Lawn Mower Engine Manual article and you fails to dwell right here, you can see from several of the articles that may suit your.
•Friction
Valve Installation Guidelines
Ensure the following guidelines, in addition to all local code requirements, are met
•The installed height, measured from the valve base, must not be less than 6'
above the highest downstream outlet controlled by the valve.
•The anti-siphon valve must not be subject to standing water which can rise to less
•The anti-siphon valve must not be installed indoors (some spillage may occur) or in
•The installation site must be accessible to allow inspection and servicing.
•Additional control valves must not be installed downstream of the anti-siphon valve.
•The valve must be installed with the top of the anti-siphon cap level.
•The valve must not be run continuously for more than 12 hours in any 24-hour peri-
•Installing a manual shut-off valve between the main water supply and automatic
valve is recommended for ease of valve maintenance and sprinkler system winteri-
zation. If water pressure exceeds 70 PSI, installing a pressure regulator should be
Installation Procedure
1.From the shut-off valve, route a supply pipe to the valve installation site. For UV
protection, use dark gray Schedule 80 PVC on the inlet (pressurized) side of the
valve and all PVC pipe installed above ground. Use Class 200 PVC on the under-
2.Flush the supply line thoroughly to remove all traces of dirt and debris.
3.For model 54000, prepare two 3/4' slip/male thread adapters with three to five
complete wraps of PTFE tape, evenly covering the threads.
4.Install the threaded adapters into the valve and tighten securely. Using PVC
primer and cement, install the valve to the PVC pipe as shown in Figure 1.
5.Route a multi-wire, direct-burial sprinkler valve cable from the sprinkler timer to the
valve location. If the cable run is less than 800', 18-gauge wire is sufficient. For
distances from 800'–2000', 14-gauge wire is recommended.
6.Using wire splice connectors, attach either wire from each valve solenoid to the
white cable wire. This wire is designated as the valve common wire. Connect the
remaining wire from the solenoid to one of the color-coded cable wires. Ensure all
CAUTION: Use grease caps or waterproof connectors on all wire splice con-
nections to prevent corrosion, connection failure and short circuit.
7.At the sprinkler timer, connect the white common wire to the output terminal
labeled “C” or “COM.” Connect each color-coded valve wire to the numbered out-
put terminals in the order you wish the valves to operate during the automatic
8.Open the shut-off valve from the water source. Test valve operation using the
6' (minimum)
From Water Source
Adapters (54000 only)
Class 200 PVC

Truetime Inc

Figure 1
Truetime 56000 Manual Lawn
Valve Common Wire
Wire Connector
Use Sch 80 PVC
Manual
Flow (GPM)5101520
1095401revC 8/13/07 10:49 AM Page 2
Posted on